Infinite Peripherals SCOM-100 Manuel d'utilisateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 75
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
SCOM-100, User guide 29
This behavior is that of a monostable timer. The
command to set an output with a pulse is:
1010,m,n,s
1010: Command ID
m: Module number (0 for SCOM-100 main
unit, 1-8 for DI-42 I/O expansion units)
n: Output number (1-4 for SCOM-100
main unit, 1-2 for DI-42 I/O expansion
units)
s: Pulse duration in seconds (1-79200)
Test the pulse command by sending an SMS:
1010,0,2,25
4.4.5 Setting a digital output after a delay
A command is available to set a digital output with an
initial delay time. The digital output’s switching behaviour
is shown on the time-based diagram below.